Introduction: office partitions, the no-build solution for dividing spaces
Dividing an open space into offices, meeting rooms or work zones is a common need in offices, clinics, academies and commercial premises in Granada and Malaga. Aluminium and glass partitions are the modern alternative to plasterboard walls: they install in 1-2 days, produce no rubble or dust, preserve natural light and can be reconfigured if business needs change.
At Tecnisun C.B. we design, manufacture and install custom partitions with STRUGAL profiles of minimal visible thickness and tempered safety glass. We work with businesses, public administrations, dental clinics, opticians, law firms and academies throughout Granada and Malaga.
💡Did you know?A 10+10 mm laminated acoustic glass partition achieves 42 dB insulation (per UNE-EN ISO 10140 test), equivalent to a 7 cm plastered brick wall. Total privacy for confidential meetings without sacrificing natural light.
Types of aluminium and glass office partitions
Depending on privacy, acoustic and aesthetic needs, we offer different configurations:
Single-glass partition: total transparency
An 8 or 10 mm tempered glass panel mounted in aluminium profiles from floor to ceiling. No intermediate transoms to maximise transparency. The standard option for offices where maintaining a sense of space and natural light matters without sacrificing physical separation.
Double acoustic glass partition: maximum privacy
Two laminated glass panels (6+6 mm or 10+10 mm) with a 20-40 mm air gap between them. Achieves acoustic insulation values of 38-44 dB (per UNE-EN ISO 10140 test), providing total privacy for meeting rooms, executive offices and medical consultations where confidentiality is legally required (GDPR).
Partition with solid lower section: function and design
Combines a 90-110 cm high opaque lower panel (melamine, wood or aluminium composite) with glass above up to the ceiling. Provides visual privacy at desk level (no one sees your screen from outside) while allowing natural light in from above. The most popular option for open-plan offices.
Sliding partition: total flexibility
Glass panels that slide along a top rail (no bottom guide) allowing the space to be opened and closed as needed. Ideal for meeting rooms that sometimes serve as open spaces for events or training. Hidden track in the suspended ceiling for an impeccable finish.
Bathroom partition: tempered glass with anti-limescale treatment
Bathroom partitions for homes, hotels and gyms use 8 mm tempered glass with factory anti-limescale treatment that repels water and limescale, keeping the glass clear with minimal effort for years. Aluminium profiles in chrome, black or white finishes.
44 dBMaximum acoustic insulation (double glass)
1-2 daysTypical installation time
0Rubble generated (no building work)
Acoustic insulation: the key in modern offices
Noise in open-plan offices is one of the main causes of workplace stress and productivity loss. Standard UNE-EN ISO 3382-3 recommends specific insulation levels for different uses:
| Space | Recommended insulation | Partition solution | Guide price/m² |
|---|
| Open workstation | 25-30 dB | Single glass 10 mm | €120-180/m² |
| Standard meeting room | 35-38 dB | Double glass 6+6 mm | €200-280/m² |
| Executive office | 38-42 dB | Double glass 10+10 mm | €280-380/m² |
| Medical consultation (GDPR) | 42-45 dB | Double laminated acoustic | €350-450/m² |
Finishes and customisation
STRUGAL aluminium profiles are manufactured in multiple finishes to integrate with any office style:
- RAL powder-coating: over 200 colours. Most requested for offices: black RAL 9005 (industrial style), white RAL 9010 (brightness), anthracite grey RAL 7016 (modern elegance).
- Anodised: natural silver, bronze and matt black. Durable, scratch-resistant metallic finish.
- Decorative glass: screen-printed with company logo, partial frosted vinyl (privacy bands at eye level), full acid-etched translucent glass.
- Smart glass (electrochromic): switches from transparent to opaque at the flip of a switch. The premium option for high-end meeting rooms.
Regulations for partitions in offices and commercial premises
Installing partitions in workspaces must comply with specific regulations:
- CTE DB-SUA (safety in use): accessible glass surfaces must be safety glass (tempered or laminated). Large-format partitions must have visual signage (bands, screen printing, vinyl) at two heights (85-110 cm and 150-170 cm) to prevent impacts.
- CTE DB-SI (fire safety): depending on the fire compartmentalisation of the premises, partitions may need fire-resistance classification (EI-30, EI-60). This particularly affects medical practices and educational centres.
- GDPR: in medical practices, law firms and financial institutions, data protection regulations require that conversations are not audible from outside. This determines the minimum acoustic insulation level of the partition.
- Accessibility: doors through partitions must meet the minimum clear opening width (80 cm), and handles must be lever-type at 80-110 cm height.
Office partition prices in Granada and Malaga (2026)
| Partition type | Price/m² | Typical 20 m² office | Installation |
|---|
| Single glass 8 mm | €100-160/m² | €1,500-2,400 | Included |
| Single glass 10 mm | €120-180/m² | €1,800-2,700 | Included |
| Double acoustic glass | €200-380/m² | €3,000-5,700 | Included |
| With solid lower section | €150-250/m² | €2,250-3,750 | Included |
| Sliding (no bottom guide) | €250-400/m² | €3,750-6,000 | Included |
| Smart glass electrochromic | €500-800/m² | €7,500-12,000 | Included |
💡Tax advantage for businessesOffice partitions are a deductible expense for Corporate Tax. They may also qualify for accelerated depreciation for SMEs (Law 27/2014), amortising 100% of the cost in the first tax year. Consult your tax adviser.
No-build installation process
Partition installation at Tecnisun is a clean, fast process:
- Visit and measurement: a technician visits the office, takes measurements and assesses acoustic, privacy and aesthetic needs.
- Floor-plan design: we present a layout with the proposed distribution, including door positions, decorative glass and wiring routes.
- Custom manufacturing: STRUGAL profiles cut and assembled at our workshop. Custom tempered glass.
- Installation in 1-2 days: mechanical fixings to floor, ceiling and walls. No masonry, no rubble, no disruption to office activity.
- Final adjustment and cleaning: door adjustment, acoustic insulation verification and glass cleaning.
Frequently asked questions about office partitions
Can partitions be installed in rented offices?
Yes. Partitions are mechanically anchored and can be removed without leaving a trace. They are the ideal solution for rented offices because they require no building work and can be taken to a new premises.
How long does the complete project take?
From initial visit to installation: 15-20 working days. The installation itself takes 1-2 days for a standard 50-100 m² office.
Are glass partitions safe if they break?
Yes. We exclusively use tempered safety glass which, if broken, fragments into small blunt harmless pieces. For tall partitions (over 3 m) or heavy-traffic areas, we use laminated glass that stays bonded to the interlayer even when broken.